GELCAST, NXGEL
No-cement refractory castables
Cement-free refractory concretes (NCC) do not contain cement, and binding is achieved through additives such as silicates, aluminates, or phosphates. They are intended for applications at very high temperatures, where traditional cementitious concretes could degrade. Linings made from cement-free concretes are characterized by, among other things, high resistance to thermal shocks and chemical corrosion.
The proper selection of refractory material for a specific application requires an appropriate analysis of the device's operating conditions. Before choosing the type of material, contact our specialist to confirm its suitability for your furnace.
Wartość: | AL2O3 (%) | SiO2 (%) | Inne wybrane składniki (%) | Gęstość pozorna (g/cm3) | Wytrzymałość
na ściskanie (N/mm2) |
Maksymalna temperatura aplikacji (°C) |
---|---|---|---|---|---|---|
Standard: | ISO 1927-3 | ISO 1927-3 | ISO 1927-3 | ISO 1927-6 | ISO 1927-6 | ISO 1927-6 |
GELCAST X521 | 68,00 | 19,0 | SiC – 10,0 | 2,70 | 45 | 1 500 |
GELCAST X2921A | 66,00 | 30,00 | 2,55 | 45 | 1 500 | |
GELCAST X5121A | 95,00 | 4,00 | 3,15 | 55 | 1 600 | |
NxGel PCO X422 | 40,00 | 46,0 | SiC – 10,0 | 2,30 | 100 | 1 200 |
NxGel PCO X1822 | 57,00 | 30,0 | SiC – 10,0 | 2,65 | 90 | 1 400 |
NxGel PCO X1722 | 66,00 | 30,0 | SiC – 10,0 | 2,45 | 35 | 1 400 |
NxGel PCO X322 | 40,00 | 46,0 | SiC – 10,0 | 2,20 | 85 | 1 200 |
The values presented are for informational purposes only and are typical for the indicated types of refractory products. These values correspond to the average results obtained in current production and are subject to fluctuations typical for the production process. PCO "Żarów" reserves the right to modify the properties of the products at any time without prior notice.
Contact us
Please select the option that best describes the subject you want to discuss with us. This will help us direct your inquiry to the right person at PCO.